CPU over 98%
Triggers when VM CPU usage exceeds 98% for 15 minutes.
The deployed alert monitors CPU usage on VMSS and triggers a Priority 2 (P2) alert if the average CPU usage exceeds 98% over a 15-minute window. This helps identify performance bottlenecks or overloaded VMs, prompting immediate action.
The alert priority Level is 2
CPU over 90%
Triggers when VM CPU usage exceeds 90% for 15 minutes.
The deployed alert monitors CPU usage on VMSS and triggers a Priority 4 (P4) alert if the average CPU usage exceeds 90% over a 15-minute window. This helps identify performance bottlenecks or overloaded VMs.
The alert priority Level is 4
OS Disk IOPS over 90%
Triggers when OS Disk IOPS usage exceeds 90% for 15 minutes.
The deployed alert monitors the OS disk IOPS consumption on VMSS. It triggers when the average percentage of IOPS consumed exceeds 90% over a 15-minute window, indicating potential disk performance saturation. When this threshold is breached, an alert is raised
The alert priority Level is 4
OS Disk IOPS over 98%
Triggers when OS Disk IOPS usage exceeds 90% for 15 minutes.
The deployed alert monitors the OS disk IOPS consumption on VMSS. It triggers when the average percentage of IOPS consumed exceeds 98% over a 15-minute window, indicating potential disk performance saturation. When this threshold is breached, an alert is raised
The alert priority Level is 2
Data Disk Bandwidth over 90%
Data Disk Bandwidth Consumed Percentage exceeds 90% for 15 minutes.
The deployed alert monitors the data disk bandwidth consumption on virtual machines. It raises an alert if the average bandwidth consumed exceeds 90% over a 15-minute window, helping to detect potential disk throughput bottlenecks.
The alert priority Level is 4
Data Disk Bandwidth over 98%
Data Disk Bandwidth Consumed Percentage exceeds 98% for 15 minutes.
The deployed alert monitors the data disk bandwidth consumption on virtual machines. It raises an alert if the average bandwidth consumed exceeds 90% over a 15-minute window, helping to detect potential disk throughput bottlenecks, prompting immediate action.
The alert priority Level is 2
Data Disk IOPS over 90%
Triggers when Data Disk IOPS usage exceeds 90% for 15 minutes.
The deployed alert monitors the Data disk IOPS consumption on VMSS. It triggers when the average percentage of IOPS consumed exceeds 90% over a 15-minute window, indicating potential disk performance saturation. When this threshold is breached, an alert is raised
The alert priority Level is 4
Data Disk IOPS over 98%
Triggers when Data Disk IOPS usage exceeds 98% for 15 minutes.
The deployed alert monitors the Data disk IOPS consumption on VMSS. It triggers when the average percentage of IOPS consumed exceeds 98% over a 15-minute window, indicating potential disk performance saturation. When this threshold is breached, an alert is raised
The alert priority Level is 2
Available memory under 2%
Triggers when the VMSS has less than 2% memory left (98% memory utilization)
The deployed alert monitors the memory usage of the VMSS. It triggers when the average memory percentage left is under 2% over a 5-minute window. This helps identify performance bottlenecks or overloaded VMSS, prompting immediate action.
The alert priority Level is 2
Available memory under 10%
Triggers when the VMSS has less than 10% memory left (90% memory utilization)
The deployed alert monitors the memory usage of the VMSS. It triggers when the average memory percentage left is under 10% over a 15-minute window. This helps identify performance bottlenecks or overloaded VMSS, prompting immediate action.